Fbt DLM26 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
4.1e. If selected a Lo-Shelv_1 (first order Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ---- [Freq.] 20Hz [Amp.] -15.0 dB [Q] ----
: : :
20kHz +15.0 dB ----
4.1f. If selected a Lo-Shelv_2 (second order Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q= ---- [Freq.] 20Hz [Amp.] -15.0 dB [Q] ----
: : :
20kHz +15.0 dB ----
4.1g. If selected a Lo-Shelv_Q (variable Q Low Shelving) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00 [Freq.] 20Hz [Amp.] -15.0 dB [Q] 0.30
: : :
20kHz +15.0 dB 20.00
4.1h. If selected a Lo-Pass_1 (first order Low Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ---- [Freq.] 20Hz [Amp.] ----- [Q] ----
: : :
20kHz ----- ----
4.1i. If selected a Lo-Pass_2 (second order Low Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ---- [Freq.] 20Hz [Amp.] ----- [Q] ----
: : :
20kHz ----- ----
4.1l. If selected a Lo-Pass_Q (variable Q Low Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00 [Freq.] 20Hz [Amp.] ----- [Q] 0.30
: : :
20kHz ----- 20.00
4.1m. If selected a Hi-Pass_1 (first order High Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ---- [Freq.] 20Hz [Amp.] ----- [Q] ----
: : :
20kHz ----- ----
4.1n. If selected a Hi-Pass_2 (second order High Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q= ---- [Freq.] 20Hz [Amp.] ----- [Q] ----
: : :
20kHz ----- ----
4.1o. If selected a Hi-Pass_Q (variable Q High Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00 [Freq.] 20Hz [Amp.] ----- [Q] 0.30
: : :
20kHz ----- 20.00
4.1p. If selected an All-Pass_1 (first order All Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q= ---- [Freq.] 20Hz [Amp.] ----- [Q] ----
: : :
20kHz ----- ----
4.1q. If selected an All-Pass_2 (second order, variable Q All Pass) filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz ----- Q=1.00 [Freq.] 20Hz [Amp.] ----- [Q] 0.30
: : :
20kHz ----- 20.00
4.1r. If selected a Band Pass filter, then the filter can be set by
the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz +0.0dB Q=1.00 [Freq.] 20Hz [Amp.] -15.0 dB [Q] 0.30
: : :
20kHz +15.0 dB 20.00
4.1s. If selected a Notch Filt filter,
then the filter can be set by the following parameters
Input A/B EQ-[x] (up to 5 filters available)
[Freq] [Gain] [Q]
-> 1000Hz -----dB Q=1.00 [Freq.] 20Hz [Amp.] ----- [Q] 0.30
: : :
20kHz ----- 20.00